PE-Inverter series

MWINV-9R122DInverter unit (9.1kVA)





9R1441外観図
■Rated Capacity 9.1kVA(Output AC200Vrms)
■Rated Output Current AC26.3Arms
■Input Voltage AC0 ~ 230Vrms
DC0 ~ 400V
■Control Power DC24V
■Breaker Built In
■Built In Sensor Vdc, Idc, Iu, Iw, Vu, Vw
■Protection Features Overcurrent, Overvoltage
■External Dimensions W330×D262×H105(mm)

Cooling Fan Breaker AC Input DC Input
Built In

Parameters Specifications Reference
AC Output Rated capacity 9.1kVA(Output AC200V)
10.0kVA(Output AC220V)
At switching frequency of 15kHz
Rated current AC26.3Arms  
Voltage Range AC0~230Vrms Dependent on input voltage
DC Input Rated Voltage DC282V  
Rated current DC35.9A  
Voltage Range DC0~400V  
AC Input Rated Voltage AC200Vrms  
Rated current AC29.2Arms  
Voltage Range AC0~230Vrms  
Cooling method Forced air cooling  
Overload capacity 120%/ minute  
Switching frequency ~20kHz Derating necessary for 15kHz and above
Dead time 3.5μsec or more  
Sensors DC voltage (Vdc) 400V / 5V  
DC current (Idc) ±50A / ±5V  
U phase / W phase current (Iu/Iw) ±50A / ±5V  
UV / WV inter voltage (Vuv / Vwv) ±400V / ±5V  
Control power supply voltage DC24V input DC22.8V~25.2V.
Recommended P/S: 24V 1.5A and above
Power Supply to Interface DC5V output Supplies to the control board 5V 2.0A
DC ±15V output Supplies to the control board ±15V 0.15A
Dielectric resistance 100MΩ or more Main circuit-pair control circuit & FG in batch
Control circuit-pair main circuit & FG in batch
Dielectric strength voltage AC1500V / minute Main circuit-pair control circuit & FG in batch
AC500V / minute Control circuit-pair main circuit & FG in batch
Weight 4.9kg  
Pin No I / O Description
1 O Supplies -15V to the control board
2,3 Ground
4 O Supplies +15V to the control board
5 O Outputs analog value of Vuv [±5V]
6 O Outputs analog value of Vwv [±5V]
7 O Outputs analog value of Iu [±5V]
8 O Outputs analog value of Iw [±5V]
9 O Outputs analog value of Vdc [+5V]
10 O Outputs analog value of Idc [±5V]
11 O Outputs analog value AN0 from SMB1
12 O Outputs analog value AN1 from SMB2
13
14 I H/W error reset input signal (active LOW)
15 I Relay drive input signal (active LOW)
16 I Break drive input signal
17 O H/W error reset output signal (active LOW)
18 O Inverted H/W error reset output signal (active HIGH)
19 I U-phase P arm gate signal (active LOW)
20 I U-phase N arm gate signal (active LOW)
21 I V-phase P arm gate signal (active LOW)
22 I V-phase N arm gate signal (active LOW)
23 I W-phase P arm gate signal (active LOW)
24 I W-phase N arm gate signal (active LOW)
25〜30
31,32 O Supplies +5V to the control board
33,34 Ground