PE-Inverter series

MWINV-1R022Inverter unit (1kVA)





■Rated Capacity 1kVA(Output AC200V)
■Rated Output Current AC2.88Arms
■Input Voltage AC0 ~ 230Vrms
DC0 ~ 400V
■Control Power DC24V
■Breaker Built In
■Built In Sensor Vdc, Idc, Iu, Iw, Vuv, Vwv
■Protection Features Overcurrent, Overvoltage
■External Dimensions W180×D160×H126.8(mm)

Cooling Fan Breaker AC Input DC Input
×

Parameters Specifications Reference
Output Rated Capacity 1kVA(Output AC200V)
1.1kVA(Output AC220V)
At switching frequency of 15kHz during forced air cooling ※1
Max Capacity 1.1kVA
Rated Current AC2.88Arms  
Voltage Range AC0~230Vrms Input voltage depend on PWM modulation
Input Rated Voltage AC200Vrms  
Rated Current AC3.2Arms  
Voltage Range (AC) AC0~230Vrms  
Voltage Range (DC) DC0~400V  
Cooling Method Forced Air Cooling ※1
Overload Capacity 120%/ minute  
Switching Frequency ~20kHz  
Dead Time 3.0μsec or more  
Sensor Monitor DC Voltage(Vdc) +500V / +5V  
DC Current(Idc) ±6.25A / ±5V  
U phase / W phase current (Iu/Iw) ±6.25A / ±5V  
UV / WV Inter Voltage (Vuv/Vwv) ±500V / ±5V  
Control power supply voltage DC24V Input DC22.8V~25.2V
Recommended power 1.5A and above
Interface Power Supply DC5V Output Supply current to control board 2.0A
DC±15V Output Supply current to control board 0.15A
Dielectric resistance 100MΩ or more Main circuit versus control circuit/FG batch
Control circuit versus main circuit/FG batch
Dielectric Strength Voltage AC1500V / minute Main circuit versus control circuit/FG batch
AC500V / minute Control circuit versus main circuit/FG batch
Weight 2.0kg  

※1 Fan is not built-in. Please attach cooling fan if necessary

Pin No I / O Description
1 O Supplies -15V to the control board
2,3 Ground
4 O Supplies +15V to the control board
5 O Outputs analog value of Vuv [±5V]
6 O Outputs analog value of Vwv [±5V]
7 O Outputs analog value of Iu [±5V]
8 O Outputs analog value of Iw [±5V]
9 O Outputs analog value of Vdc [+5V]
10 O Outputs analog value of Idc [±5V]
11 O Outputs analog value AN0 from SMB1
12 O Outputs analog value AN1 from SMB2
13
14 I H/W error reset signal
15 O Relay drive signal
16 I Break drive signal
17 O H/W error reset signal (active LOW)
18 O H/W error output (active LOW)
19 I U-phase P arm gate signal (active LOW)
20 I U-phase N arm gate signal (active LOW)
21 I V-phase P arm gate signal (active LOW)
22 I V-phase N arm gate signal (active LOW)
23 I W-phase P arm gate signal (active LOW)
24 I W-phase N arm gate signal (active LOW)
25~30
31,32 O Supplies +5V to the control board
33,34 Ground