Home > Power Supply/Charge & Discharge System > Battery Charge & Discharge System Specifications

Battery Charge & Discharge System

pCUBE-CDS Specifications

Parameters Specifications
Model MWCDS-1008-C02 MWCDS-1250-C02
pCUBE model loaded MWBFP3-1008-C02 MWBFP3-1250-C02
Total voltage Measurement range
( resolution)
H range -1.1V$301C80.1V(1mV) -2V$301C500V(1mV)
L range -1.01V$301C5.01V(0.1mV) -1.1V$301C50V(1mV)
Measurement accuracy ±0.1% of F.S. ±0.1% of F.S.
Current Measurement range
( resolution)
H range -250A$301C250A(1mA) -35A$301C35A(1mA)
L range -25.1A$301C25.1A(1mA) -4.01A$301C4.01A(1mA)
Measurement accuracy ±0.2% of F.S. ±0.2% of F.S.
Power Measurement range ( resolution) VoltageH、CurrentH -10.1kW$301C10.1kW(1W) -11.6kW$301C11.6kW(1W)
VoltageH、CurrentL -2.01kW$301C2.01kW(1W) -2.02kW$301C2.02kW(1W)
VoltageL、CurrentH -1.26kW$301C1.26kW(1W) -1.7675kW$301C1.7675kW(1W)
VoltageL、CurrentL -126W$301C126W(0.1W) -202W$301C202W(0.1W)
Measurement accuracy ±0.3% of F.S.
Current capacity Measurement accuracy 1mAh
Power capacity Measurement accuracy 1mWh
Cell voltage Measurement range
( resolution)
0V$301C5V(1mV)
Measurement accuracy ±0.1% of F.S.
Channel number 16ch( Extensible by 16ch )
Cell voltage (thermocouple) Measurement range
( resolution)
-40℃$301C100℃(0.1℃)
Measurement accuracy below 2℃
Channel number 32ch ( Extensible by 32ch )
External analog input Measurement range
( resolution)
-5V$301C5V(1mV)
Measurement accuracy ±1% of F.S.
Channel number 2ch
Others Measurement cycle 10ms$301C600s
Protection function System protection, output voltage/current protection,
emergency stop ( external contact input )
Size 570mm(W)×1100mm(H)×1000mm(D)
Weight about 210kg

●The accuracy above is applicable in temperature +23℃±5℃ and humidity below 70%.

■Application of Battery Charge & Discharge System

Parameters Specifications
Charge & discharge command CC charge/ CC discharge/ CP charge/ CP discharge/ CC-CV charge/CC-CV discharge/
CP-CV charge/ CP-CV discharge/ CC cell CV charge/ CC cell CV discharge/
CP cell CV charge/ CP cell CV discharge/Memory operation/ Stop/ Loop ( 65,535 max)
Shift condition Time/ Current/ Total voltage/ Cell voltage/ Power/ Charge current capacity/
Discharge current capacity/ Charge & discharge current capacity/
Charge power capacity/ Discharge power capacity/Charge & discharge power capacity/
Current capacity ratio/ Cell temperature/ External analog input
Stop condition Time/ Current/ Total voltage/ Cell voltage/ Charge current capacity/
Discharge current capacity/ Charge & discharge current capacity/
Charge power capacity/Discharge power capacity/
Charge & discharge power capacity/ Cell temperature

● To measure the Cell temperature, uses thermocouple of K type.

■Size



To EU customers:
Myway Plus is in the process of obtaining CE Marking for our products and they are not available
for EU applications today. For further enquiry, please send an enquiry form to us.